Watlow F4T Temperature & Process Controller
More Information
Configurations for Watlow's F4T can be custom tailored to meet the scaling needs of a tremendous range of equipment and applications while providing exactly the hardware types required for compatibility. The F4T controller also features a 4.3 inch, color, graphical touch panel. Combining power, flexibility and functionality, this new controller offers unmatched versatility, and its best-in-class ease of use could very well make user manuals a thing of the past.
Watlow F4T Specifications
Description
1-4 PID loops with profiles & data logging options
Control/Limit Loops
4/4
Max Monitor Channels
24
Alarms
Up to 14
Mounting
Front panel or flush mount
Profiling
Yes
Max Output
10A SSR
Phase Configurations
1
Ambient Operating Range
-18 to 50C°C (0 to 122F°F)
Agency Approvals
UL/EN 61010 Listed, UL508, CSA, FM (limit), RoHS by design, China RoHS Level 2, W.E.E.E., CE
Communication Protocols
Standard Bus, Modbus® TCP, Modbus® RTU, SCPI, USB 2
Supported Controllers
F4T, Flex Modules (FM), Composer PC software
Operating Requirements
NA
TRU-TUNE®+ Adaptive Control
Yes
Remote Limit Reset
Yes
Display Height
4.3" PCAP color graphical touch
1-4 PID loops with profiles & data logging options
Control/Limit Loops
4/4
Max Monitor Channels
24
Alarms
Up to 14
Mounting
Front panel or flush mount
Profiling
Yes
Max Output
10A SSR
Phase Configurations
1
Ambient Operating Range
-18 to 50C°C (0 to 122F°F)
Agency Approvals
UL/EN 61010 Listed, UL508, CSA, FM (limit), RoHS by design, China RoHS Level 2, W.E.E.E., CE
Communication Protocols
Standard Bus, Modbus® TCP, Modbus® RTU, SCPI, USB 2
Supported Controllers
F4T, Flex Modules (FM), Composer PC software
Operating Requirements
NA
TRU-TUNE®+ Adaptive Control
Yes
Remote Limit Reset
Yes
Display Height
4.3" PCAP color graphical touch
Documentation
User Manuals
QUICK START GUIDE: F4T CONTROLLER AND D4T DATA LOGGER
QUICK START GUIDE: MIXED INPUT/OUTPUT FLEX MODULES
QUICK START GUIDE: HIGH DENSITY INPUT/OUTPUT FLEX MODULES
QUICK START GUIDE: MODBUS RTU COMMUNICATION FLEX MODULE
F4T User Guide: Installation & Troubleshooting
F4T Controller Setup and Operation User's Guide
F4T Feature Add - Instructions
Brochures
F4T with INTUITION Process Controller
F4T with INTUITION Process Controller - Chinese
PRODUCT FEATURE: Email and Text Alert Feature for F4T Controller and D4T Data Logger
CAD Drawings
F4T CAD Drawings
Training & Education
COMPOSER FAQ
COMPOSER® Tutorial: Alarms
COMPOSER® Tutorial: Cascade Control
COMPOSER ® Tutorial: Connecting Signals Between Devices
COMPOSER® Tutorial: Control Loops
COMPOSER® Tutorial: Function Block Diagram Overview
COMPOSER® Tutorial: Profile Engine
COMPOSER® Tutorial: Using Function Block Diagram
F4T FAQ
F4T - Startech USB 3.0 to Ethernet Install
F4T/D4T Batch Processing - Using Automatic Profiles
F4T/D4T Batch Processing - Using Manual Profiles
F4T/D4T Batch Processing - Using Without a Profile
F4T/D4T Batch Processing - Creating & Importing a Part/Profile List
Catalogs
Controller Catalog (Section) - Data Loggers
Controller Catalog (Section) - Integrated Multi-Function Controllers
Controller Catalog (Section) - Temperature and Process Controllers
Controller Catalog (Section) - Software
Sensor & Controller Catalog
Retrofit Guides
SERIES F4 to F4T Retrofit Guide
SERIES F4P Specification Sheet
SERIES F4S Specification Sheet
Software & Demos
COMPOSER® V3.10.24
Sample F4T 32-bit Modbus RTU Packet
F4T Register List for Communication Protocols and LabView
LabVIEW Driver .zip Archive v6.0.109 [February 2018]
LabVIEW Driver Installer v6.0.109 [February 2018]
F4T Firmware 3.06.0011 with Release Notes
F4T FIRMWARE 4.08.0029 (use with 4.00 or newer)
F4T FIRMWARE 4.08.0029 (use with 3.06 or older)
F4T D4T EDS (Electronic Data Sheet) file for EtherNet/IP
Specification Sheets
F4T Specification Sheet
F4T with INTUITION Specifications - Chinese
White Papers
Meeting Nadcap Requirements with Modern Data Logging Methods
Other Documents
Setting Up Email and Text Alerts for Watlow’s F4T Controller
Watlow F4T Modules
Watlow F4T High Density I/O Flex ModulesWatlow F4T high density I/O flex modules serve as the interface between real-world devices and the F4T system ..... →
|
Watlow F4T Limit Control ModulesFunctions of Watlow F4T limit control modules include limit control with universal input ..... →
|
Watlow F4T Modbus® RTU Communication ModulesWatlow F4T Modbus® RTU communication modules provide the necessary connections to various industrial fieldbus networks ..... →
|
Watlow F4T Mixed I/O ModulesWatlow F4T mixed I/O modules include a variety of input hardware options, such as universal input, T/C, RTD 2 - or 3-wire, 0-10VDC ..... →
|
ProductsHeaters Sensors Temp. Controls Controls & Relays Hot Runners Heat Trace Cold Weather Wire Accessories Insulation Pressure Relief Slide Products |
ServicesCredit Application Order Tracking Delivery Programs Stocking Programs R.M.A. Request Catalog Request Custom Quick |
CompanyAbout Testimonials Legal & Copyright Accessibility Blog |
SupportContact Account Managers FAQ Technical Information Instructional Videos Helpful Links Downloads Line Card |
Popular ProductsChromalox Heaters Watlow Heaters Watlow EZ-ZONE® Watlow F4T MDI Hot RunnerProheat is an authorized distributor of Chromalox and Watlow heater products. Band Heaters Cartridge Heaters Strip Heaters Tubular Heaters Immersion Heaters Hot Runner Nozzles Hot Runner Systems Hot Runner Controllers |
© Proheat, Inc.